A water bill that jumped 30% with no change in usage. A ceiling stain that keeps reappearing after patches. A soft spot in the flooring with no visible source. These are signs of a hidden leak that's been running long enough to cause structural damage — and every day it runs is money lost and damage accumulating. Masters Plumbing Service uses acoustic ground microphones, thermal imaging cameras, and precision pressure testing in Deep Gap, NC to locate leaks without speculative demolition.
📞 Call +1-855-718-1500 — Find Your Leak Today
A pressure test tells us a leak exists and how much water is escaping. Detection equipment tells us precisely where.
Pressurized supply line leaks create a distinctive low-frequency sound as water escapes the pipe and contacts surrounding soil or structure. Our acoustic listening devices amplify this signal, filtered for background noise, so we can walk a grid pattern and triangulate the loudest point — often to within 6–12 inches of the actual break.
Thermal imaging is particularly effective inside insulated wall cavities and for finding the extent of moisture spread beyond the immediate leak point. It tells us not just where the pipe is failing but how far the moisture has already traveled.
We isolate the supply system, pressurize it to operating pressure, and monitor pressure over a timed hold period. Any pressure drop confirms active water loss from the supply side. By isolating zones — hot side vs. cold side, section by section — we narrow down which branch of the supply system is leaking before the detection phase begins.
For leaks that don't produce sufficient acoustic signature — very slow leaks, polyethylene pipe, or leaks deep under concrete — we can introduce a nitrogen/hydrogen tracer gas mixture into the isolated pipe and use a calibrated gas detector at the surface to find where the gas escapes. The detection sensitivity can locate leaks that produce no discernible pressure drop during a standard timed test.
Our detection service covers the full property, not just the obvious locations.
Confirmed slab leak location is documented with a marked point on the floor and provided to you in the written detection report, with coordinates relative to fixed reference points for the repair crew.
We document the thermal anomaly, mark the approximate pipe location, and recommend a minimal access cut rather than a wide wall opening.
We mark the ground above the detected leak location so the repair crew opens only the section they need to.
Pool plumbing — suction and return lines buried between the equipment pad and the pool shell — can develop leaks at fittings or in the pipe body that appear as unexplained water loss. We pressure-test the pool plumbing circuit, isolate the return and suction lines separately, and use acoustic detection to find which line and where.
Multi-story buildings, commercial kitchens, retail spaces, and industrial properties have complex pipe networks where a supply or drain leak can go undetected through multiple floors before surfacing. We approach commercial detection systematically — zone by zone pressure isolation, thermal scan of suspect surfaces, and acoustic confirmation.
Insurance claims for water damage from hidden leaks typically require documentation that the leak was not visible or detectable without specialized equipment. Our detection report includes: pressure test results confirming active water loss, detection method used, thermal imagery or acoustic mapping showing leak location, and technician certification information.
Here's exactly how a Masters Plumbing Service leak detection call plays out.
We start at the meter. All fixtures off, we watch the meter for 10 minutes. Movement confirms active water loss from the supply side. We also check for any visible evidence — water stains, soft floors, moisture readings with a moisture meter at suspect wall surfaces.
Zone isolation is the step that turns "there's a leak somewhere in the house" into "the leak is on the hot side supply, between the water heater and the master bath."
We document findings with thermal images and note detection readings at multiple grid points to triangulate the strongest signal.
You receive a written detection report including pressure test results, detection method summary, leak location (described relative to fixed reference points), and thermal imagery. If you want us to repair the leak, we quote the repair and execute immediately. If you have your own plumber, the report gives them everything they need.

My water bill doubled over three months with no change in usage. Masters Plumbing Service came out, confirmed the meter was moving with everything off, isolated the cold supply to the kitchen as the failing branch, and used the acoustic device on the slab to pinpoint a location 4 feet from the outside wall under the kitchen floor. The repair crew opened a 10-inch circle in the tile, found a pinhole in a copper elbow exactly where detection said it would be. I was skeptical acoustic detection was that precise — it was.
Our insurance company required professional leak detection documentation before approving the claim. Masters Plumbing Service's written report with pressure test data and thermal imagery was exactly what the adjuster needed. Claim approved. The detection cost was covered as part of the claim.
Commercial building where water costs were running 40% above baseline for six months. Masters Plumbing Service ran a systematic zone-by-zone pressure isolation across four floors, narrowed the loss to the third-floor kitchen supply branch, and located the failure with thermal imaging at a concealed valve body in the ceiling. No damage to the finished ceiling.

Masters Plumbing Service provides professional Leak Detection for residential and commercial properties throughout Deep Gap and the surrounding Deep Gap, NC service area. Detection appointments available most weekdays and Saturdays.

Call now to schedule — most detection appointments available within 24–48 hours.
📞 Call +1-855-718-1500 Now